Adenovirus Antigen Rapid Test

Product Details
Customization: Available
Type: Detection Card
Syringe: None
Still deciding? Get samples of US$ 0/box
Request Sample
Manufacturer/Factory, Trading Company
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (19)
  • Adenovirus Antigen Rapid Test
  • Adenovirus Antigen Rapid Test
  • Adenovirus Antigen Rapid Test
  • Adenovirus Antigen Rapid Test
  • Adenovirus Antigen Rapid Test
  • Adenovirus Antigen Rapid Test
Find Similar Products

Basic Info.

Model NO.
HADV026G
Breathing Pattern
None
Animal Anesthesia Machine Control Method
None
Assay Time
5-10 Minutes
Delivery Time
3~5days After Get Payment
Payment
T/T, Western Union, Paypal
Customized
Accpet
Transport Package
Carton
Specification
10Tests/Kit
Trademark
PETX
Origin
Hangzhou
HS Code
38220010
Production Capacity
5000000PCS/Year

Product Description

INTENDED USE
Adenovirus Antigen Rapid Test is a rapid chromatographic immunoassay for the qualitative detection of human Adenovirus antigen in human stool specimen. The test results are intended to aid in the diagnosis of adenovirus infection and to monitor the effectiveness of therapeutic treatment.
Adenovirus Antigen Rapid Test
MATERIALS

Materials Provided
  • Individually packed test devices
  •  Package insert
  • Disposable pipettes
 
Materials Required but Not provided
  • Specimen collection container
  • Timer
 

TEST PROCEDURE

Bring tests, specimens, and/or controls to room temperature (15-30°C) before use.
  1. Remove the test from its sealed pouch, and place it on a clean, level surface. Label the device with patient or control identification. For best results the assay should be performed within one hour.
  2. SPECIMEN PREPARATION
Unscrew the sample bottle, use the attached applicator stick attached on the cap to transfer small piece of stool (4-6 mm in diameter; approximately 50 mg - 200 mg) into the sample bottle containing specimen preparation buffer . For liquid or semi-solid stools, add 100 microliters of stool to the vial with an appropriate pipette. Replace the stick in the bottle and tighten securely. Mix stool sample with the buffer thoroughly by shaking the bottle for a few seconds.
  1. ASSAY PROCEDURE
3.1 Hold the sample bottle upright with the tip point toward the direction away from the test performer, snap off the tip.
3.2. Hold the bottle in a vertical position over the sample well of the test card, deliver 3 drops (120-150 μL) of diluted stool sample to the sample well (S) and start the timer.
Avoid trapping air bubbles in the specimen well (S), and do not add any solution to the result area.
As the test begins to work, color will migrate across the result area in the center of the device.
3.3. Wait for the colored band(s) to appear. Read the result between 5 - 10 minutes. A strong positive sample may show result earlier.
Do not interpret the result after 10 minutes.
As the test begins to work, color will migrate across the result area in the center of the device.

 

     INTERPRETATION OF RESULTS            

    Adenovirus Antigen Rapid Test

  • POSITIVE: Two or three colored bands appear on the membrane. One band appears in the control region (C) and another band appears in the test region (T).
    NEGATIVE: Only one colored band appears in the control region (C). No apparent colored band appears in the test region (T).
    INVALID: Control band fails to appear. Results from any test which has not produced a control band at the specified read time must be discarded. Please review the procedure and repeat with a new test. If the problem persists, discontinue using the kit immediately and contact your local distributor.
    NOTE:
  • The intensity of color in the test region (T) may vary depending on the concentration of analytes present in the specimen. Therefore, any shade of color in the test region should be considered positive. Note that this is a qualitative test only, and cannot determine the concentration of analytes in the specimen.
  • Insufficient specimen volume, incorrect operating procedure or expired tests are the most likely reasons for control band failure.

PERFORMANCE CHARACTERISTICS

Table: Adenovirus Antigen Rapid Test vs. Latex Agglutination
Method Latex Agglutination Total Results
Adenovirus Antigen
Rapid Test
Results Positive Negative
Positive 165 1 166
Negative 1 225 226
Total Result 166 226 392
Relative Sensitivity: 99.40% (95%CI: 96.69%~99.98%)  
Relative Specificity: 99.56% (95%CI:97.56%~99.99%) 
Accuracy: 99.26% (95%CI:98.17%~99.94%)
SPECIFICITY
Cross reactivity with following organisms has been studied at 1.0 x 108 organisms/ml. The following organisms were found negative when tested with the Adenovirus Rapid Test Device (Feces).
Staphylococcus aureus Neisseria gonorrhea Acinetobacter spp
Pseudomonas aeruginosa Group B Streptococcus Salmonella choleraesius
Enterococcus faecalis Proteus vulgaris Gardnerella vaginalis
Group C Streptococcus Enterococcus faecium Acinetobacter calcoaceticus
Klebsiella pneumoniae Proteus mirabilis E.coli
Branhamella catarrhalis Candida albicans Chlamydia trachomatis
Hemophilus influenzae Neisseria meningitides  

Adenovirus Antigen Rapid TestAdenovirus Antigen Rapid Test