• Fiv Felv The Feline Immunodeficiency Virus Ab Feline Leukemia AG Combo Rapid Test
  • Fiv Felv The Feline Immunodeficiency Virus Ab Feline Leukemia AG Combo Rapid Test
  • Fiv Felv The Feline Immunodeficiency Virus Ab Feline Leukemia AG Combo Rapid Test
  • Fiv Felv The Feline Immunodeficiency Virus Ab Feline Leukemia AG Combo Rapid Test
  • Fiv Felv The Feline Immunodeficiency Virus Ab Feline Leukemia AG Combo Rapid Test
  • Fiv Felv The Feline Immunodeficiency Virus Ab Feline Leukemia AG Combo Rapid Test

Fiv Felv The Feline Immunodeficiency Virus Ab Feline Leukemia AG Combo Rapid Test

Type: Detection Card
Box Size: 15cm*10cm*8cm
Packing: 80 Box Per Carton
Carton Size: 68cm*44cm*44cm
Transport Package: Carton
Specification: 10 test per box
Customization:
Manufacturer/Factory, Trading Company
Gold Member Since 2021

Suppliers with verified business licenses

Rating: 5.0/5
Zhejiang, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (18)

Basic Info.

Model NO.
JCA104C
Trademark
PETX
Origin
China
HS Code
3822001000
Production Capacity
50000PCS/Month

Product Description

  • INTENDED USE
  • The FIV Ab/FeLV Ag Combo Rapid Test is a combined cassette to differentially diagnose the presence of Feline Immunodeficiency antibody and Feline Leukemia Virus antigen in cat's blood specimen.
    Assay Time:  5-10 minutes
    Specimen: Serum, plasma or whole blood
  • PRINCIPLE
  • The FIV Ab/FeLV Ag Combo Rapid Test is based on sandwich lateral flow immunochromatographic assay.
  • REAGENTS AND MATERIALS
  • Test devices
  • Disposable capillary droppers 
  • Assay buffers for FIV and FeLV assay
  • Products Manual
  • STORAGE AND STABILITY
  • The kit can be stored at room temperature (4-30°C). The test kit is stable through the expiration date (24 months) marked on the package label. DO NOT FREEZE. Do not store the test kit in direct sunlight.
  • SPECIMEN PREPARATION AND STORAGE
  • Specimen should be obtained and treated as below.
  • Serum or plasma: collect the whole blood for the patient cat, centrifuge it to get the serum, or place the whole blood into a tube which contains anticoagulants to get plasma.
  • Whole blood: collect fresh blood for use directly or make anticoagulant blood for storage at 2-8ºC.
  • 2.  All specimen should be tested immediately. If not for testing right now, they should be stored at 2-8ºC.
  • TEST PROCEDURE
  • Allow all materials, including specimen and test device, recover to 15-25ºC before running the assay.
  • Take out the test device from the foil pouch and place it horizontally.
  • Using the capillary dropper to place 10μL of the prepared specimen into the sample hole "S" of the test device. Then drop 3 drops (approx. 90μL) of the assay buffer into the sample hole immediately.
  • Interpret the result in 5-10 minutes. Result after 10 minutes is considered as invalid.
Fiv Felv The Feline Immunodeficiency Virus Ab Feline Leukemia AG Combo Rapid Test
 
  • INTERPRETATION OF RESULTS
  • Positive (+): The presence of both "C" line and zone "T" line, no matter T line is clear or vague.
  • Negative (-): Only clear C line appear. No T line.
  • Invalid: No colored line appears in C zone. No matter if T line appears.
  • PRECAUTIONS
  • All reagents must be at room temperature before running the assay.
  • Do not remove test cassette from its pouch until immediately before use.
  • Do not use the test beyond its expiration date. 
  • The components in this kit have been quality control tested as standard batch unit. Do not mix components from different lot numbers.
  • All specimens are of potential infection. It must be strictly treated according to the rules and regulations by local states.
  • LIMITATION
  • The FIV Ab/FeLV Ag Combo Rapid Test is for in vitro veterinary diagnosis use only. All result should be considered with other clinical information available with veterinarian. It is suggested to apply a further confirmative method such as Western Blot when positive result was observed.

Fiv Felv The Feline Immunodeficiency Virus Ab Feline Leukemia AG Combo Rapid Test
J&G Biotech Ltd (Reg. No.: 08419172)
326 Cleveland Road, London, England E18 2AN, UK
Fiv Felv The Feline Immunodeficiency Virus Ab Feline Leukemia AG Combo Rapid Test
Fiv Felv The Feline Immunodeficiency Virus Ab Feline Leukemia AG Combo Rapid Test
Fiv Felv The Feline Immunodeficiency Virus Ab Feline Leukemia AG Combo Rapid Test
Fiv Felv The Feline Immunodeficiency Virus Ab Feline Leukemia AG Combo Rapid Test
Fiv Felv The Feline Immunodeficiency Virus Ab Feline Leukemia AG Combo Rapid Test
Fiv Felv The Feline Immunodeficiency Virus Ab Feline Leukemia AG Combo Rapid Test
Fiv Felv The Feline Immunodeficiency Virus Ab Feline Leukemia AG Combo Rapid Test
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
Registered Capital
1500000 USD
Plant Area
>2000 square meters